藍色一般代表純凈,紅色一般代表危險。所以藍色一般都是純凈水,紅色是排污水。不過PE管顏色可以隨機的,畢竟只是為了區分而已,沒有說非要哪種顏色的接廢水管的。
B. 污水工程-反滲透翻譯(2)
c. RO unit (membrane array)
RO unit is the actuator of the whole desalting system, whose role is to remove soluble salts, colloids, organic compounds, and microorganisms in the water. The unit is equipped with three set ROs, each has 219m3/h net output, more than 75% recovery rate, and more than 97% total desalting rate (within the life-term). RO membrane adopts TML20-370 anti-contamination RO membrane element proced by Japan Toray Company [Length: 40〃; Diameter: 8〃; Membrane area: 370 square feet (34 m2); Single membrane desalting rate: 99.5%]. Each set RO adopts design of two-sections per grade (需要自己核實) and 62 seven-meter-long pressure containers lining in 41:21 matrix, each pressure container is internally equipped with seven membranes, thus each RO set needs 434 membranes and a total of 1736 membranes for 4 sets. The mean membrane flux is 14.7LMH being in accordance with super-filtration water RO design guideline and having large margins.
c. RO cleaning unit
RO pressure is generally operating at 1.3-1.8MPa. After long-term running, RO membrane array may be contaminated by some contaminations uneasy to be washed off, for example, long-term accumulation of trace salt scales and some organic compounds can result in declining of the performance of the membrane moles and higher running pressure, and therefore, RO membrane array must be cleaned with some chemicals to recover its normal desalting function. When super-filtration was used as pretreatment, it should be cleaned every 3 months, and every cleaning lasts about 2-4 hours. The unit is equipped with a set of cleaning equipment including a stainless steel safeguard filter, two cleaning pumps (1 in use & 1 for preparation) and a cleaning agent tank. The cleaning unit is operated automatically.
d. RO washing unit
RO system is equipped with automatic washing unit, which washes the membrane element surface with RO-proced water as supply to avoid contamination sediment on the membrane surface. The unit is equipped with two wash pumps (1 in use & 1 for preparation) and a washing tank.
e. Control instrument
Serials of online measuring instruments are equipped to control and monitor the normal running of RO system, including conctivity instrument, flow meter, pressure meter, sampling apparatus, and high-low voltage protecting switch, etc. RO is operated automatically, whose condensed water discharging flow is fixed according to the steady-flow-valve installed in the pipelines, and the proced water is set with high-pressure proof bursting membrane.
C. 反滲透凈水機要排「廢水」,好像一般比例都在1:3,是不是太浪費了
購買過反滲透凈水機的親應該知道,工程師會從凈水機中接出一根PE管用於排「濃縮水」(消費者一般叫廢水),這些水中含有大量的有害物質和雜質,如果不排放,極易造RO膜的堵塞。而1:3的排放比例(即三杯自來水才能制出一杯凈化水)屬於業內最常見的比例,這樣的比例能保證濾芯使用壽命更長,出水品質更好。當然不同的水質,比例其實是需要專門調整的。而由於每戶人家飲水占家庭用水比例僅2%,一年在「廢水」上的花費也就幾十塊錢,所以換個節水馬桶,比你將廢水二次利用更有利於節約水費。畢竟買凈水機的核心目的是為了喝到健康水。
因此深圳革隆
家用凈水器代理廠家
在此提醒廣大消費者,以及選擇代理凈水器廠家的經銷商朋友們,在選擇凈水器廠家的時候,一定要注意凈水器廠家的實力,一些小的凈水器廠家由於規模小,操作市場有限,在凈水器配件方面缺東少西,在衛生批件方面,也沒達到衛生指標等等問題。為凈水器經銷商開拓市場帶來了阻力,不利於經銷商後期的發展。也為用戶後期的使用帶來了不必要的麻煩。選擇凈水器廠家很重要,希望廣大凈水器經銷商重視。
D. RO反滲透純水機的廢水的比例是多少
一級反滲透產水率為百分之30 廢水量70%,對於串級過濾 最高產水率內能達到70%
每次制水(容應該是一滿桶)時間要6個小時,且要排出5倍的濃水,這應該是反滲透純水機。而且機器安裝使用時間應該滿兩年了(按機器說明書要求使用條件),果真如此的話,是應該換RO膜了
E. 處理污水,RO為一級一段運行,15隻膜殼(6元件),有濃水迴流。問反滲透裝置的進水量最低不能低於多少
應該是說反滲透的濃水流量不能低於多少,因為進水量多,如果回收率過高,流速還是很慢內的。其中與水的容水質也有關系,牽涉到很多細節。
以陶氏為例,當進水為井水,SDI<1 以陶氏8寸 BW365系列元件來說,最小設計濃水流量為3T/H,通過你設計的回收率,算出產水量,濃水流量和產水流量之和就是最小進水量了。最好的辦法是使用膜的設計軟體計算一下就很清楚了。
F. 怎麼區分反滲透一段二段
看出水率 和 電導率 反滲透一段 出水率75% 電導率也就是十以下 反滲透二段 出水率可以達到80%-85% 電導率可以達到五以下
G. 反滲透純水機廢水比例是多少,怎麼算的
純水機凈化後的水是純凈水,口感好,廢水也多。比如柏佳反滲透純水機「內廢水比1:3」
廢水比指容的是單位時間內純水機產生的純水與排放的廢水的體積比。就是指純水機在制水時,每制一份 純水就會產生3份廢水。廢水中含有鐵銹、病毒,細菌、沙石等雜質,將會被排掉。
I. 凈水器上有幾根水管
這個問題要看你的凈水機具體是什麼型號的,如果是簡易的凈水機只有一進一出兩根水管,如果是超濾凈水機,有的是兩根水管,有的多一個廢水管,所以是三根水管,如果是普通反滲透凈水機有進水管,出水管,廢水管和壓力桶管,所以是四根水管,如果是雙出水的凈水機,分為進水管,廢水管,壓力桶管,凈水管和純水管,所以是五根水管,如果是大流量的凈水機可以省一根壓力桶管,所以大流量的凈水機單水的是三根水管,雙出水的是四根水管,希望可以幫到你。
J. 污水處理反滲透一級二級進水 濃水 段間 高壓泵後 壓力普遍升高什麼原因,清洗後無效果怎麼處理。
反滲透系統的故障通常至少出現下列情況之一: 標准化後產水量下降,通常需要提高運行壓力來維持額定的產水量; 標准化後脫鹽率降低,在反滲透系統中表現為產水電導率升高; 壓降增加,在維持進水流量不變的情況下,進水與濃水間的壓差增大; 下面將詳細的討論上述三種主要故障標准化後產水量下降 RO系統出現標准化後產水量降低,可根據下面三種情況尋找原因: RO系統的第一段產水量降低,則存在顆粒類污染物的沉積; RO系統的最後一段產水量降低,則存在結垢污染; RO系統的所有段的產水量都降低,則存在污堵; 根據上述症狀,出現問題的位置,確定故障的起因,並採取相應的措施,依照"清洗導則"進行清洗等.另外反滲透系統出現產水量下降的同時還會伴隨有脫鹽率降低、升高等情況. 1、因為一段反滲透污染,造成一段膜元件進水流道堵塞,造成原水無法有效進入一段膜元件,而且進入一段的原水因為膜元件污染不能穩定產水,因此一段進水壓力增加,產水量下降; 2、於此同時,因為進入一段的原水量減少,故一段濃水量下降,因此二段進水量也相應減少,所以二段進水壓力降低,相應二段濃水壓力也下降; 3、因為反滲透受到污染堵塞,在高壓運行條件下,機組的產水水質也會相應下降,產水電導率因此上升。